Vigor Technology
MEMS Inclinometer
    SST20 Inclinometer
    SST100 Inclinometer
    SST200 Inclinometer
    SST300 Inclinometer
    SST400 Inclinometer
    CAN Inclinometer
    CANopen Inclinometer
    DeviceNet Inclinometer
    Ethernet Inclinometer
    USB Inclinometer
    ZigBee Inclinometer
    Wi-Fi Inclinometer
    GPRS Inclinometer
    PWM Inclinometer
    TOC Tilt Switch
    GPS Inclinometer
    Ranged Inclinometer
    Gyro Inclinometer
    FFT Inclinometer
    Thermal-shock-proof Inclinometer
    Submersible Inclinometer
    Tilt Beam Sensor
    Explosion-Proof Inclinometer
    In-Place Inclinometer
Dynamic Inclinometer
    SST800 Dynamic Inclinometer
    SST810 Dynamic Inclinometer
Servo Inclinometer
    SST500 Inclinometer
Levelmeter
    SST900 Levelmeter
Application Software
    iAngle Mobile Application Software
    iSS1 PC Application Software
Installing Tools
    Adjustable base with micrometer screw
    Adjustable base with bubble
    Fixed Installation Base
    Portable Battery Pack
Thermometer
    VTIR0812 Infrared Thermometer
    VTIR1816 Infrared Thermometer
    VTIR3816 Infrared Thermometer
 
Current location:Vigor Technology > MEMS Inclinometer> SST
SST100 Inclinometer
Features

- High stability & performance-cost ratio
- Small size,light weight,easy to integrate
- Cross-axis sensitivity up to ±0.3%FS
- Omni-direction alarm & dual alarms,analog & digital outputs
- Full-seal,resistant to vibration and shock
- IP67 protection

Applications

Mobile construction Machinery, Factory automation, Solar equipment, Transportation machinery, Medical equipment,etc.
Performances Size & Wiring Descriptions Our Ability How to Order Documents

Table1 SST141/2,SST151/2,SST161/2 Inclinometer

Product type SST141,SST142,SST151,SST152,SST161,SST162 with analog/digital output
Measurement range ±5° ±10° ±15° ±30° ±45° ±60° ±90° ±180°
Accuracy(@25℃ ) ±0.1°
Temperature drift coefficient /℃ @ -20~65℃ ±0.004° ±0.005° ±0.009°
Resolution 0.003°
Repeatability ±0.02°
Offset repeatability ±0.02°
Offset ±0.02°
Measurement axis 1 axis:SST141,SST151,SST161
2 axis:SST142,SST152,SST162
Response time 0.3s @ t90
Cross-axis sensitivity ±0.3%FS
Digital output
for SST161,SST162
RS232(optional RS485),update rate:5Hz(default),10Hz,20Hz optional
Format: 19200 baud,8 data bits,1 start bit,1 stop bit,none parity,ASCII
CAN2.0: according to ISO11898-2 standard, 5k~1MBit/s baud rate, support 127 nodes, built in high speed photoelectric isolator
Voltage output
for SST141,SST142
0.5~4.5VDC
Output Impedance:0.3Ω,load impedance:< 100Ω
Current output
for SST151,SST152
4~20mA
Output Impedance:50MΩ,load impedance:150~250Ω
Cold start warming time 60s
Power supply With digital/voltage output:9~36VDC,consumption≤20mA
With current output:16~36VDC,consumption≤40mA
Power supply reject ratio ≥85dB
Operation temperature range -40~85℃
Storage temperature range -40~100℃
EMC According to EN 61000
Insulation resistance ≥100MΩ
MTBF 150000h/times
Shock 100g@11ms,three-axis,half-sine
Vibration 8grms,20~2000Hz
Protection IP67
Housing 6061-T6 Aluminum alloy
Connecting Standard: Binder712 connector,optional: metal pigtail
Cable 7-wire shielded cable with tensile reinforcement,heavy duty up to 30Kg
Weight ≤240g(without connector and cable)

Table2 SST122 Inclinometer

Product type SST122 with double alarms output
Control range ±5° ±10° ±15° ±30° ±45° ±60°
Control direction ±0.004° ±0.004° ±0.004° ±0.004° ±0.005° ±0.005°
Control direction X &Y axis
Resolution 0.02°
Alarm angle error ±0.1°
Alarm trigger delay 1.0s
disconnect delay 1.0s
Repeatability ±0.05°
Hysteresis ±0.05°
Switch endurance ≥5000000 times
point 2points/axis
setting Fixed before delivery
delay time 0.3~5.0s,default 1.0s
Output NO or NC(default NO),OC output,internal isolation
switch capacity 1A@5~48VDC,inductive load
supply 9~36VDC,≤50mA(when no load)
Alarm control supply 9~36VDC
Connecting Metal pigtail
Cable 7-wire shielded cable with tensile reinforcement,heavy duty up to 30Kg
Power supply reject ratio ≥85dB
Operation temperature range -40~85℃
Storage temperature range -40~100℃
EMC According to EN 61000
Insulation resistance ≥100MΩ
MIBF 150000h/times
Shock 100g@11ms,three-axis,half-sine
Vibration 8grms,20~2000Hz
Protection IP67
Housing 6061-T6 Aluminum alloy
Weight ≤240g(without connector and cable)

Table3 SST130 Inclinometer

Product type SST130 with Omni-direction alarm output
Control range ±5° ±5° ±5° ±5° ±5° ±5°
Temperature drift
/℃ @ -20~65 ℃
±0.004° ±0.004° ±0.004° ±0.004° ±0.005° ±0.005°
Control direction Omni-direction(combined with X and Y axis)
Resolution ±0.02°
Alarm angle error ±0.1°
Alarm trigger delay 1.0s
Alarm disconnect delay 1.0s
Repeatability ±0.05°
Hysteresis ±0.05°
Switch endurance ≥5000000 times
Alarm point One alarm point
Alarm point setting Online setting via RS232
Alarm time delay 0.3~5.0s,Default value 1.0s,adjustable.
Output NO or NC(default NO),OC output,internal isolation
Alarm switch capacity 1A@5~48VDC
Online setting via RS232 Zero setting: available setting range:≤±5°
Alarm point setting: Set any angle as alarm point,default value is ±3°
RS232 interface Format:19200 baud,8 data bits,1start bit,1stop bit,none parity,ASCII
Power supply 9~36VDC,≤50mA
Alarm control supply 9~36VDC
Connecting Standard: Binder712 connector,optional: metal pigtail
Cable 7-wire shielded cable with tensile reinforcement,heavy duty up to 30Kg
Power supply reject ratio ≥85dB
Operation temperature range -40~85℃
Storage temperature range -40~100℃
EMC According to EN 61000
Insulation resistance ≥100MΩ
MIBF 150000h/times
Shock 100g@11ms,three-axis,half-sine
Vibration 8grms,20~2000Hz
Protection IP67
Housing 6061-T6 Aluminium alloy
Weight ≤260g(without connector and cable)

Table4 SST111&SST121 Inclinometer

Product type SST111 & SST121 inclinometer with alarm output
Control range ±5° ±10° ±15° ±30° ±45° ±60°
Temperature drift
/℃ @ -20~65℃
±0.004° ±0.004° ±0.004° ±0.005° ±0.005° ±0.005°
Control direction Single Axis: SST111
Dual Axis: SST121
Resolution 0.02°
Alarm angle error ±0.1°
Alarm trigger delay 1.0s
Alarm disconnect delay 1.0s
Repeatability ±0.05°
Hysteresis ±0.05°
Switch endurance ≥5000000 times
Alarm point Single Axis(SST111): one alarm point of X Axis
Dual Axis(SST121): one alarm point of each Axis
Alarm point setting Online setting via RS232
Alarm time delay 0.3~5.0s,Default 1.0s,adjustable
Output NO or NC(default NO),OC output,internal isolation
Alarm switch capacity 1A@5~48VDC
Online setting via RS232 Zero setting: available setting range:≤±5°
Alarm point setting: Set any angle as alarm point,default value is ±3°
RS232 interface Format:19200 baud,8 data bits,1start bit,1stop bit,none parity,ASCII
Power supply 9~36VDC,≤50mA
Alarm control supply 9~36VDC
Connecting Standard: Binder712 connector,optional: metal pigtail
Cable 7-wire shielded cable with tensile reinforcement,heavy duty up to 30Kg
Power supply reject ratio ≥85dB
Operation temperature range -40~85℃
Storage temperature range -40~100℃
EMC According to EN 61000
Insulation resistance ≥100MΩ
MIBF MIBF150000h/times
Shock 100g@11ms,three-axis,half-sine
Vibration 8grms,20~2000Hz
Protection IP67
Housing 6061-T6 Aluminium alloy
Weight ≤240g(without connector and cable)